R and V Works FF6 Informacje Techniczne Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 80
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
Compressor Application Manual
15
IV
1 - Problems and Solutions
1.1 - Voltage
1.1.1 - No voltage at power supply
Check using a voltmeter or test
lamp.
1.1.2 - Very low voltage at power supply
To eliminate problems of voltages
below 103 V (115 V nominal) and
198 V (220 V nominal), at the end
of the Manual we recommend the
use of a voltage stabilizer.
When the compressor does not
start, the problem can be solved
most often by using the right
starting capacitor.
1.1.3 - Very high voltage
To eliminate the problem of
voltages above 132 V (115 V
nominal) and 240 V (220 V
nominal) we recommend the use
of a voltage stabilizer.
2 - Electrical Parts
2.1 - Interrupted electric cable or wiring
Using a test lamp or ohmmeter, check if
the cable or wiring is not interrupted. Also
check the plug.
Przeglądanie stron 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 79 80

Komentarze do niniejszej Instrukcji

Brak uwag