Compressor Application Manual
51
Compressor
Capacitor to be
used in capillary
systems
Capacitor to be
used in expansion
valve systems
The relays of the aforementioned
compressors have the following
characteristics:
• terminals 11 and 13 are longer than
normal to permit the capacitor's
connection;
• it does not have the copper wire bridge
between terminals 11 and 13. The
compressor, therefore, will only start if
the corresponding capacitor is installed.
3.2 - FG AK and FG HAK compressors
FG AK and FG HAK compressors, LST
version, instead of using electromechanical
relays (as those used in F models), use a
PTC type relay and thermal protector.
VIVI
378 to 454 "F (115VAC) or
233 to 280 "F (150VAC)
124 to 149 "F (180VAC) or
64 to 77 "F (250VAC)
378 to 454 "F (115VAC) or
233 to 280 "F (150VAC)
124 to 149 "F (180VAC) or
64 to 77 "F (250VAC)
378 to 454 "F (115VAC)
124 to 149 "F (180VAC)
378 to 454 "F (115VAC)
124 to 149 "F (180VAC)
FFI12BX 115V60Hz
FFI12BX 220V60Hz
FFI12HBX 115V60Hz
FFI12HBX 220V60Hz
270 to 324 "F (115VAC)
270 to 324 "F (150VAC)
282 to 339 "F (180VAC)
378 to 454 "F (150VAC)
FF8.5BX 115V60Hz
FF10BX 115V60Hz
FF10HBX 115V60Hz
FFI12HAX 115V60Hz
270 to 324 "F (115VAC)
270 to 324 "F (150VAC)
282 to 339 "F (180VAC)
378 to 454 "F (150VAC)