Compressor Application Manual
63
To prevent excessive water in the
compressor, the tubes must be kept sealed
at all times. The rubber plugs must only be
removed immediately before brazing the
tubes to the system's tubes (as short a time
as possible, never more than 15 minutes).
Refrigeration system manufacturers, who use
inflammable refrigerants, such as R 600a, are
recommended to develop a correct charging
method, leakage test, etc., to guarantee that all
necessary safety procedures are adopted.
The same care/procedures must be adopted by
the refrigeration professional who may
eventually operate R 600a systems.